# Network Capture (GVSP Tap)

> Capture a GigE Vision RHEED camera's stream as it arrives at the gateway

**Network (GVSP Tap)** is the default frame source. A GigE Vision camera sends its frames to the RHEED software over the network as a GVSP stream. The tap receives copies of those packets on the same computer and reassembles them into frames. It never opens the camera and never sends it commands, so it works even when the RHEED software holds the camera exclusively.

```text theme={null}
Camera ─GVSP/UDP─► camera-facing ─► RHEED software
                   network adapter
                        │
                        └─ copy (Pktmon)
                               ▼
                        RHEED integration ─► Atomscale
```

Because the tap only listens, it can't ask the camera to resend lost packets. Frames with missing packets are dropped and counted, so a clean network path matters.

## Before You Start

* **Windows**, with the camera connected to this computer.
* **[Integration admin access](https://docs.atomscale.ai/gateway/admin-access.md) turned on.** Capturing packet copies needs administrator rights. If you skipped it during setup, the integration's page offers to turn it on when you start it.
* **The RHEED software acquiring** from a GigE Vision camera that streams to this computer (unicast).
* **Whole packets.** The camera's packet size must fit the network adapter's MTU and every switch on the path. If the camera uses jumbo packets, enable jumbo frames on the camera-facing adapter and switches.
* **English Windows.** The default capture mode reads Windows Packet Monitor's English output, so it fails on a localized Windows installation. On non-English Windows, choose another mode in [Capture Modes](#capture-modes), or use [Standard capture (GenTL)](https://docs.atomscale.ai/gateway/rheed/camera.md).

## Set Up Network Capture

The defaults need no input, so a new integration is ready to start as soon as it is added.

**1. Add the integration**

Add a **RHEED Camera (GenTL)** integration. The app opens its page with Start it when ready.
**Frame Source** is already **Network (GVSP Tap)** and every capture setting is **Auto**. For an
existing integration that uses another source, stop it, click
Configure, select **Network (GVSP Tap)**, and apply.

**2. Start it while the RHEED software acquires**

Check that the RHEED software is acquiring, then click
Start Integration. If admin access is off, the page shows
"Network (GVSP Tap) needs Integration admin access, which is off on this computer. Without it,
it can't capture." Click Enable admin access, have an
administrator approve the Windows prompt, and click Start again. With admin access on, the
integration adds its own firewall rule and starts without a prompt.

**3. Choose the camera if asked**

With **Camera IP Address** blank, Start looks for GigE Vision cameras on this computer's
networks without changing anything on them. With one camera, it uses it and remembers it for
later runs. If several answer, the page shows Several GigE Vision cameras answered. Choose the RHEED camera.
Click Choose, pick the camera from the list (such as
**Camera A: 169.254.14.85**), apply, and start again.

**4. Check the health verdict**

The health summary in the **Health** section of the integration's page shows Tuning while it measures the
stream, then Healthy once frames arrive whole. Idle with No frames are arriving from the camera.
is expected while the RHEED software is not acquiring. The activity log shows
Data item opened: RHEED Stream @ … once frames arrive, and the stream appears in Atomscale as
Stream Active.

**5. Optional: set the stage rotation**

If the stage rotates, you can get first results sooner by entering its speed. Stop the
integration, set **Stage Rotation** to the speed in RPM, apply, and start it again. If you leave
it blank, Atomscale detects whether the stage rotates.

If the camera's address changes later, for example a `169.254.x.x` address after a restart,
capture follows it and logs The camera … moved from … to …; capture follows it. To pin a camera,
click Detect in **Camera IP Address** while the integration is
stopped, or type the address.

To check the network path before uploading anything, turn on Show advanced settings, turn on
Diagnostics Only, apply, and start. The **Activity Logs** report packet counts, incomplete
frames, and frame brightness without uploading. Turn Diagnostics Only off when you're done.

## Capture Modes

**Capture Mode** (advanced) selects how Windows provides the packet copies. Keep the default unless diagnostics show no packets.

| Capture Mode | Description |
| - | - |
| **NIC Miniport Tap (Pktmon)** | The default. Uses the built-in Windows Packet Monitor (Pktmon) to capture at the network adapter, below vendor filter drivers such as Allied Vision Vimba's GVSP filter driver, so it sees packets those drivers would otherwise hide. Requires Windows 10 version 1809 or later. |
| **Windows IP Capture** | Receives copies of the traffic Windows accepted on the network adapter. Works when the RHEED software receives the stream through the normal Windows network stack and no vendor filter driver consumes it. |
| **Raw UDP Socket** | Receives raw UDP copies. Copies can be incomplete while another application owns the stream; prefer Windows IP Capture. |
| **Promiscuous NIC Capture** | For a switch mirror port connected to a second network adapter (see below). Requires **Allow Promiscuous Capture**; enable it only with your network administrator's approval. |

### Pktmon and Other Users

Packet Monitor is shared by the whole computer. While the integration captures, it owns Packet Monitor's state, using a filter named `AtomscaleRheedGvsp`. It never stops or changes someone else's capture: if another Packet Monitor capture or filter is active when it starts, it refuses to start and says so. Stop the other capture, or run `pktmon status` in an elevated PowerShell window to see what is running.

The integration picks the Packet Monitor component for the camera's network adapter automatically. If several components match equally, it asks you to set **Pktmon Component ID**: run `pktmon list` in an elevated window and enter the ID of the adapter that carries the camera traffic.

### Mirror Port Setup

If neither Pktmon nor Windows IP Capture sees the packets, a managed switch can mirror the camera's traffic to a second network adapter:

1. Mirror the camera port's incoming traffic to a spare switch port, and connect it to a second network adapter on the workstation.
2. Leave the vendor filter driver enabled on the primary adapter and unbind it from the second (monitor) adapter only. Vendor software updates can re-enable the binding, so check it after each update.
3. Give the monitor adapter a static address outside the camera subnet, with no gateway and no DNS.
4. In advanced settings, set **Capture Mode** to **Promiscuous NIC Capture**, turn on Allow Promiscuous Capture, set **Capture Interface IP** to the monitor adapter's address, and set **Original Stream Destination IP** to the primary camera-facing adapter's address.
5. Confirm the mirror path supports the camera's packet size.

## How the Tap Follows the Stream

* **Network adapter.** With **Capture Interface IP** blank, the integration finds the adapter that receives the camera's stream each time it starts. If it can't, the error says why and what to set.
* **Stream port.** With **Stream Destination Port** on Auto, the tap learns the port from the first complete, valid frame. After the camera goes quiet for **Traffic Report Timeout** (10 seconds), it releases the port and validates the next acquisition the same way. A change in image size or format is validated again without a restart.
* **Packet loss.** If more than half the frames in a 10-second window are incomplete, the activity log warns. A second such window in a row makes the tap re-validate the stream. 300 incomplete frames in a row with no complete frame stop the integration with an error.

## Troubleshooting

| Symptom or message | Cause and fix |
| - | - |
| Network (GVSP Tap) needs Integration admin access, which is off on this computer. | Click Enable admin access on the integration's page, or turn it on in **Settings**. See [Integration Admin Access](https://docs.atomscale.ai/gateway/admin-access.md). |
| … needs an update to Integration admin access … | A desktop app update shipped a newer admin access component. Click Update admin access. See [When It Needs Repair](https://docs.atomscale.ai/gateway/admin-access.md#when-it-needs-repair). |
| Could not start integration with admin access: … | The admin access setup needs repair or an update. See [When It Needs Repair](https://docs.atomscale.ai/gateway/admin-access.md#when-it-needs-repair). |
| Several GigE Vision cameras answered. Choose the RHEED camera. | Click Choose on the integration's page, pick the camera, apply, and start again. |
| No GigE Vision cameras answered on this computer's networks … | The camera search got no reply. Check camera power and Ethernet, and that Windows Firewall or endpoint security is not blocking the reply. Or enter the camera IP manually. |
| The camera from the last run, …, did not answer discovery, so capture waits for it. | The remembered camera is off or unplugged. If it was replaced, click Detect on **Camera IP Address** to choose the new one. |
| Idle: Not recording because the camera image is too dark. | Frames arrive, but none are bright enough to count as active. If the beam is on, set **Minimum Mean Intensity** lower, or click Auto Manage to relearn it. See [Recording Sessions](https://docs.atomscale.ai/gateway/rheed/sessions.md). |
| … reported more than one IP address … | The camera has an address conflict. Resolve it on the camera network, then detect again. |
| Could not find the network adapter that receives camera …'s stream. | The message names the reason. If another camera answered, its address changed: update **Camera IP Address**. If the camera answered on several adapters, set **Capture Interface IP** to the camera-facing adapter's IPv4 address. |
| pktmon-busy: another Pktmon capture is active … or pktmon-foreign-filters: … | Another Packet Monitor user is active. See [Pktmon and Other Users](#pktmon-and-other-users). |
| pktmon-unavailable: … | Packet Monitor is missing or Windows is older than version 1809. Update Windows, or set **Capture Mode** to **Windows IP Capture**. |
| … several Pktmon miniport components match interface … | Set **Pktmon Component ID** as described in [Pktmon and Other Users](#pktmon-and-other-users). |
| no UDP traffic from … after … | No packets reach the tap. Check that the RHEED software is acquiring, and that **Camera IP Address** and **Capture Interface IP** are right. If a vendor filter driver may be consuming packets, keep **Capture Mode** on Pktmon or use a mirror setup. |
| UDP traffic from … arrives but no GVSP image leader was recognised … | The camera answers but isn't streaming to this computer. Start acquisition in the RHEED software, and check that no vendor filter driver consumes the stream. |
| Warnings about lossy windows, or frames incomplete | Packets are lost or fragmented. Enable jumbo frames along the whole path or lower the camera's packet size, and check the computer's load. |
| A mirror setup sees packets, but none match | **Original Stream Destination IP** is wrong. Diagnostics name the destination address most rejected packets carried; enter that address. |

For problems with session boundaries or missing data items, see [Recording Sessions](https://docs.atomscale.ai/gateway/rheed/sessions.md#troubleshooting).


This documentation is built and hosted on [Mintlify](https://mintlify.com), a developer documentation platform.