Before You Start
- The camera vendor’s SDK or driver package installed on this computer. It provides the GenTL producer, a file ending in
.cti.- The producer must match the integration’s architecture: the 64-bit SDK on 64-bit Windows.
- Most SDKs register their producer in the
GENICAM_GENTL64_PATH(orGENICAM_GENTL32_PATH) environment variable, which the integration searches. If you installed the SDK after starting Atomscale, quit and reopen Atomscale so it sees the variable.
- The RHEED software able to acquire from the camera.
- For GigE cameras, a network path that supports the camera’s packet size. If the camera uses jumbo packets, enable jumbo frames on the camera-facing network adapter and on any switch in between.
Set Up Standard Capture
You can ask the Gateway assistant to set Frame Source to Standard (GenTL) and apply the producer path or camera ID you provide. Install the vendor SDK or driver yourself first.1
Select the frame source
Add a RHEED Camera (GenTL) integration, or stop an existing one and click
Configure. Set Frame Source to Standard (GenTL).
2
Choose the producer and camera
- GenTL Producer: leave blank to search automatically, or enter the full path to the
.ctifile, for exampleC:\Program Files\Vendor\producer.cti. - Camera: leave blank if the producer sees exactly one camera. Otherwise enter its serial number or ID exactly as the producer reports it.
3
Fill in the growth details
Optionally set Stage Rotation to the stage speed in RPM for faster first results on a
rotating stage. Left blank, Atomscale detects whether the stage rotates. Review the
session settings.
4
Apply the configuration
Click Apply Configuration. The integration loads the producer
and looks for the camera; if it can’t, the affected field shows why (see
Troubleshooting). It also runs a quick camera check and writes the result to
the activity log.
5
Start the integration
Click Start Integration. On Windows, the first start asks an
administrator to approve an inbound firewall rule for the camera’s network stream (see
Windows Firewall Rules). Without it, a GigE camera’s
frames may be blocked.
6
Acquire
Start acquisition in your RHEED software. The activity log shows Data item opened: RHEED Stream @ …,
and the stream appears in Atomscale as Stream Active.
Check the Camera with Diagnostics
Run diagnostics when setting up a new camera or when frames don’t arrive. They check the camera and stream without creating data items or uploading.- Stop the integration, open Configure, and turn on Show advanced settings.
- Turn on Diagnostics Only and apply.
- Start the integration, start acquisition in the RHEED software, and read the Activity Logs. Diagnostics report whether a frame arrived, the frame size and pixel format, frame brightness, and common problems such as a packet size larger than the network adapter supports or software that holds the camera exclusively.
- Stop the integration, turn Diagnostics Only off, and apply.
Troubleshooting
For problems with session boundaries or missing data items, see Recording Sessions.